Series XV Single Output to 30A 420 Vac No Heat Sink, Hybrid Relay Part Number XV46D30K Description 30A, 420 Vac Part Number Explanation XV 46 D 30 K NOTES 1) Line Voltage (nominal): 46 = 420 Vac 2) Switch Type: D = Zero-cross turn-on 3) Control Range: K = 20-30 Vdc, *C = 12 Vdc also available MECHANICAL SPECIFICATION M4 1.10 (28) O.19 (O4.7) FEATURES/BENEFITS * Industry standard package * Combines the best of solid-state and electromechanical relays * Tight zero-cross window for low EMI * Control LED * Internal output protection * High immunity to surges DESCRIPTION The Series XV relay combines the best of solid-state and electromechanical technology. The relay is designed in a touch-proof hockey-puck package. The XV relay switches current up to 30A without a heat sink. Visual control status is provided as a standard. Elimination of the heat sink conserves space and makes the XV ideal for numerous applications. APPLICATIONS * Interface applications * Heating Control * Light/Lamp control * Contactor driver * Fan speed control * HVAC controls APPROVALS Model XV46D30K is UL recognized. UL File Number: E128555. WEIGHT: 5.64 oz (160g) 1.70 (43.2) .35 (9) 1.87 (47.6) 1.00 (25.4) 1.77 (45) 1.75 (44.5) M3.5 Figure 1 - XV relay; dimensions in inches (mm) INPUT (CONTROL) SPECIFICATION Min Control Range* Input Current Range Must Turn-Off Voltage Input Resistance (Typical) Reverse Voltage Protection Control Frequency TYPICAL APPLICATION 20 31 Max 30 41 10 640 30 1 Units Vdc mAdc Vdc Ohms Vdc Hz .27 (6.8) 2.41 (61.3) CONTROL CHARACTERISTIC 45 40 A1+ t3 Input Current (mA) 35 30 25 20 15 10 SSR t2 T1 Vc A1- Supply t1 EMR VL L1 Load LED 5 0 0 5 10 15 20 25 30 35 Figure 2 - XV relay Control Voltage (V) Figure 3 - XV relay (c) 2003 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com XV 1 XV\032003\Q1 Series XV OUTPUT (LOAD) SPECIFICATION Min Operating Range Peak Voltage Load Current Range Motor Load Current (See Figure 4) On-State Voltage Drop Zero-Cross Window (Typical) Off-State Leakage Current (60Hz) Turn-On Time (60Hz) Turn-Off Time (60Hz) Off-State dv/dt Maximum di/dt (Non-repetitive) Operating Frequency I t for fuse matching (<8.3ms) 2 SURGE CURRENT Unit Vrms Vpeak Arms Apeak 200 250 Max 420 800 30 7.5 12 0.1 Arms 150 Maximum Surge Current Rating (Non-Repetitive) 240 Apeak 0.3 12 2 12 20 500 50 440 288 40 V V mA ms ms V/s A/s Hz AS 2 100 50 0 1 10 100 1000 Number of Cycles Figure 4 - XV relay LIFETIME EXPECTANCY 5 At maximum rated current (Resistive load) 4 10 6 Operations ENVIRONMENTAL SPECIFICATION Min Operating Temperature Storage Temperature Input-Output Isolation Output-Case Isolation Life Expectancy -40 -40 Max 90 100 4000 4000 See Figure 5 Unit C C Vrms V 3 2 1 0 100 200 300 400 500 Load Voltage (V) Figure 5 - XV relay NOTES: 1. Electrical Specifications at 25C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom options, contact factory. XV 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2003 TELEDYNE RELAYS XV\032003\Q1 |
Price & Availability of XV46D30K |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |